Low voltage · Main distribution boards
Type-tested main distribution for the projects that can't afford downtime.
Our LV switchboard range spans three families — type-tested BlokSeT and Prisma manufactured under Schneider Electric license, plus EPOS partial type-tested boards for custom distribution layouts. Form 4 separation, internal arc containment to 100 kA, and engineered for commercial, industrial, and critical-load environments across the Kingdom.
- Voltage
- Up to 690 Vac · 50 / 60 Hz
- Main busbar rating
- Up to 7,000 A
- Short-time current
- Up to 100 kArms / 1 s
- Internal arc
- 100 kA / 0.4 s · IEC TR 61641
The range
Two type-tested families, engineered for the most demanding LV applications.
From the form-4 BlokSeT main board for critical distribution, to the modular Prisma panel for tertiary buildings, to a configurable EPOS board where a full type test is not specified.
- Up to 690 Vac · Schneider licensed01 / 3
Type-tested switchboard — BlokSeT
Up to 30% energy savings
Manufactured under Schneider Electric license and fully type-tested to IEC 61439-1 and -2. The reference for main distribution boards in commercial buildings, hospitals, airports, and industrial plants — modular, scalable, and Form-4 compliant for the highest level of internal separation.
Up to 690 Vac · 7,000 A busbar · 100 kArms / 1 s · Form 4 · IP 54
- Up to 690 Vac · Schneider licensed02 / 3
Distribution panels — Prisma
Schneider Electric's Prisma distribution range manufactured under license. Engineered for floor- and wall-mounted distribution boards in commercial and tertiary buildings where modularity, safety, and aesthetics all matter — compatible with the full Schneider LV protection portfolio.
Up to 690 Vac · 3,200 A busbar · Form 4 · IP 55 · IEC 61439-1/-2/-3
- Up to 690 Vac · Partial type tested03 / 3
Partial type-tested switchboard — EPOS
Engineered to IEC 61439 as a partial type-tested system (PTTA). Flexible distribution-board configurations for projects requiring custom layouts where a full type-tested switchboard is not specified — built in the same Madinah facility, to the same quality system.
Up to 690 Vac · Configurable busbar · PTTA · IEC 61439 · IP configurable
Side-by-side specifications
Full technical comparison across the LV range.
| Specification | BlokSeT | Prisma | EPOS |
|---|---|---|---|
| Type-test compliance | Fully type tested | Fully type tested | Partial type tested (PTTA) |
| Rated voltage | Up to 690 Vac | Up to 690 Vac | Up to 690 Vac |
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Main busbar rating | Up to 7,000 A | Up to 3,200 A | Configurable |
| Distribution busbar rating | Up to 3,200 A | Up to 1,600 A | Configurable |
| Short-time current (1 s) | Up to 100 kArms | Up to 65 kArms | Application-specific |
| Peak withstand current | Up to 220 kApeak | Up to 143 kApeak | Application-specific |
| Internal arc | 100 kA / 0.4 s | Application-specific | — |
| Form of separation | Up to Form 4 | Up to Form 4 | Configurable |
| Earthing systems | TT · IT · TN-S · TN-C | TT · IT · TN-S · TN-C | TT · IT · TN-S · TN-C |
| Degree of protection | Up to IP 54 | Up to IP 55 | Configurable |
| Compliance | IEC 61439-1, -2 | IEC 61439-1, -2, -3 | IEC 61439 (PTTA) |
| Schneider license | Supported | Supported | — |
| Smart-ready | Supported | Supported | Optional |
BlokSeT
- Type-test compliance
- Fully type tested
- Rated voltage
- Up to 690 Vac
- Frequency
- 50 / 60 Hz
- Main busbar rating
- Up to 7,000 A
- Distribution busbar rating
- Up to 3,200 A
- Short-time current (1 s)
- Up to 100 kArms
- Peak withstand current
- Up to 220 kApeak
- Internal arc
- 100 kA / 0.4 s
- Form of separation
- Up to Form 4
- Earthing systems
- TT · IT · TN-S · TN-C
- Degree of protection
- Up to IP 54
- Compliance
- IEC 61439-1, -2
- Schneider license
- Supported
- Smart-ready
- Supported
Prisma
- Type-test compliance
- Fully type tested
- Rated voltage
- Up to 690 Vac
- Frequency
- 50 / 60 Hz
- Main busbar rating
- Up to 3,200 A
- Distribution busbar rating
- Up to 1,600 A
- Short-time current (1 s)
- Up to 65 kArms
- Peak withstand current
- Up to 143 kApeak
- Internal arc
- Application-specific
- Form of separation
- Up to Form 4
- Earthing systems
- TT · IT · TN-S · TN-C
- Degree of protection
- Up to IP 55
- Compliance
- IEC 61439-1, -2, -3
- Schneider license
- Supported
- Smart-ready
- Supported
EPOS
- Type-test compliance
- Partial type tested (PTTA)
- Rated voltage
- Up to 690 Vac
- Frequency
- 50 / 60 Hz
- Main busbar rating
- Configurable
- Distribution busbar rating
- Configurable
- Short-time current (1 s)
- Application-specific
- Peak withstand current
- Application-specific
- Internal arc
- —
- Form of separation
- Configurable
- Earthing systems
- TT · IT · TN-S · TN-C
- Degree of protection
- Configurable
- Compliance
- IEC 61439 (PTTA)
- Schneider license
- —
- Smart-ready
- Optional
Where it's deployed
Engineered for the buildings, hospitals, and industrial plants of Vision 2030.
The LV main board is where a building's power chain becomes its own — everything downstream of the transformer depends on its integrity. We specify Form-4 BlokSeT where reliability and standardised safety levels are non-negotiable.
- 01
Commercial buildings
Main distribution boards for office towers, mixed-use developments, retail, and hospitality. Form-4 BlokSeT specified where high reliability and standardised safety levels are required.
- 02
Healthcare facilities
Hospital electrical infrastructure where uninterrupted power is a clinical requirement. Configurable with automatic transfer schemes, UPS integration, and life-safety load segregation.
- 03
Airports and transportation
LV distribution for terminals, control towers, runway lighting, and ground support facilities. Engineered for 24/7 operational requirements and the load profiles specific to aviation.
- 04
Industrial and manufacturing
Main and sub-distribution for production facilities, process plants, and manufacturing complexes. Compatible with MCC integration and process automation systems.
- 05
Data centers and critical infrastructure
Mission-critical distribution where redundancy and arc-fault containment are mandatory. Form-4 separation, internal arc to 100 kA, and N+1 backup configurations.
- 06
Education and government
University campuses, ministerial complexes, and embassies. Configurable for both standalone substations and larger distribution networks.
An MV source steps down through a transformer to the Form-4 LV main switchboard, which fans out through outgoing ways to sub-distribution, a motor control centre, and a final distribution board — each feeding its loads.
Engineered to standard
Type-tested. Independently certified. Schneider-licensed.
The LV switchboard family is designed and type-tested per the IEC standards covering low-voltage assemblies, distribution boards, and arcing due to internal fault.
IEC standards compliance
- IEC 61439-1Low-voltage switchgear and controlgear assemblies — general rules.
- IEC 61439-2Power switchgear and controlgear assemblies.
- IEC 61439-3Distribution boards intended to be operated by ordinary persons.
- IEC TR 61641Guide for testing under conditions of arcing due to internal fault.
Management systems and licensing
- ISO 9001 : 2015
- ISO 14001 : 2015
- ISO 45001 : 2018
- Schneider Electric · Licensed (BlokSeT, Prisma)
Documentation
Everything your engineering team needs to specify, install, and commission.
Datasheets, dimensional drawings, type-test certificates, and an installation manual, released on engagement to the named project team.
Family datasheet
PDF · ~7 MB
All three ranges, full specifications, single-line diagrams, and standard configurations.
Request copy
Dimensional drawings
PDF + DWG · ~10 MB
CAD-ready cubicle outlines, busbar layouts, and standard cabling configurations.
Request copy
IEC type-test certificates
PDF · ~5 MB
Independent type-test certificates including IEC 61439 and internal arc per IEC TR 61641.
Request copy
Installation and commissioning manual
PDF · ~4 MB
Installation procedures, commissioning checklists, torque specifications, and interlock procedures.
Request copy
LV switchboard documentation is released to qualified buyers. Send your single-line diagram, load schedule, or board schedule and we will return the bundle — with an indicative board layout — within one working day.
Often deployed together
Related products in the TEPCO portfolio.
The families most often specified alongside LV switchboards on Saudi building and industrial projects.
Upstream
Medium voltage switchgear
LV switchboards sit downstream of MV switchgear in a project's electrical hierarchy. Specify both together for integrated design and single-source supply.
View MV switchgear
Factory-built
Package substations
Integrate LV switchboards with transformer and MV protection in a single factory-built unit — faster commissioning, fewer interfaces, one point of accountability.
View package substations
Digital
Smart grid and automation
Add real-time monitoring, energy management, and remote control to any LV installation. BlokSeT smart features deliver up to 30% energy savings.
View smart grid
Ready to specify low voltage switchboards?
Send us your single-line diagram or technical requirement, and our Madinah engineering team will respond within 24 hours with an indicative board layout and configuration.